Six controlled stages turn polyethylene granulate into a finished insulation product.

02Technology

Engineered for Performance

01

Raw Material

Polyethylene granulate is received, checked against specification and dried before it enters the line.

02

Compounding

The melt is dosed with a foaming agent and a nucleating additive - the ratio here decides the final cell size.

03

Extrusion

The material is extruded and expands as it leaves the die, forming the closed-cell structure that carries the insulation value.

04

Lamination

Lavsan or foil facing is bonded in line, and self-adhesive grades receive their adhesive and liner in the same pass.

05

Quality Control

Every batch is checked for density, thickness, cell structure and bond strength of the facing before it is released.

06

Cutting and Packing

Product is cut to the ordered width and length, wound, marked and packed for dispatch.

01 / 06

04Our Production

Inside the Plant

Extrusion, lamination, cutting and packing all happen on site, which is what makes cut-to-size supply a normal order rather than an exception.

09Quality

Quality Is Engineered

THERMOGOODS certificate of conformity, test reports and registration documents. Each document can be opened or downloaded.

Certificates & Documents

  • Certificate of Conformity

    Extruded polystyrene foam boards, grades PPS 30 and PPS 35, conform to GOST 15588-2014. National Certification System of the Republic of Uzbekistan, scheme 3.

    No. UZ.SMT.01.0103.122312186 · valid until 19.12.2027

    Certification body “O‘zbekiston ilmiy-sinov va sifat nazorati markazi” (UzTest), O‘ZAK.MS.0103

  • Test Report

    Physical and mechanical tests of PPS 30 and PPS 35 boards to GOST 15588-2014: compressive and bending strength, thermal conductivity, water absorption, density and dimensions.

    No. 28352p of 18.12.2024

    Polymer products testing laboratory, UzTest, O‘ZAK.SL.0309

  • Fire Test Report

    Fire performance of PPS 30-35 boards: combustibility group to GOST 30244 and ignitability group to GOST 30402.

    No. 763-С of 18.12.2024

    Research Institute of the Ministry of Emergency Situations of Uzbekistan, laboratory O‘ZAK.SL.0179

  • Certificate of State Registration

    Registration of THERMOGOODS LLC in the Unified State Register of Business Entities.

    THERMOGOODS LLC · reg. No. 892002 of 14.09.2020 · TIN 307728306

    Public Services Centre, Bektemir district, Tashkent

10Thickness Calculator

How much insulation does it take

Set the operating conditions and see what the layer does. The section on the right is drawn to the numbers on the left.

Indicative figure: steady-state conduction through the insulation layer at λ = 0.035 W/(m·K), surface resistances excluded. It does not replace a design calculation.

⌀ 60.3 + 2 × 20 mm20
Heat loss
19.4
W per metre of pipe
Thermal resistance
0.57
m²·K/W
Outer diameter
100
mm

Products covering this thickness

11Request Quote